Valentin Bartenev 08e0082e07 Fixed discovering of modules on 64-bit big-endian systems.
The nxt_conf_map_object() function used nxt_int_t for NXT_CONF_MAP_INT, which
was 8 bytes long on 64-bit systems.

But the nxt_port_main_start_worker_handler() used it to map into the int field
of the nxt_common_app_conf_t structure, which was 4 bytes.  As the result, on
a 64-bit big-endian system all the meaningful module type numbers were assigned
into the gap above the "type" field.

The bug was discovered on IBM/S390x.